Method 1 - Requires SERVICE key
1) Turn off the AC switch.
2) Set the mode switch to (SRV’) position.
3) Turn on the AC switch.
4) Turn to (SRV) position from (SRV’) position.


Method 2
1) Set the mode switch to PGM2 position.
2) Turn off the AC switch.
3) While holding down JOURNAL FEED key and RECEIPT FEED key, turn on the AC switch.

Method 2 requires Service Line JOB#926-B to be set to "4".

Note: When disassembling and reassembling always power up using method 1 only. Method 2 will not reset the CKDC10.