Connecting Till to Laptop

Created by Jon Mitchell, Modified on Wed, 7 Dec, 2022 at 3:26 PM by Jon Mitchell

1. Find IP of laptop as this needs to be entered in to the till


2. Every eprom till should be 192.168.1.1


ON TILL

- Payment

- 99

- MGR 1

- 9999 as password

- Payment

- Mode

- 7 PGM2 Mode

- 2 Setting

- 20 MWS Setting


IP Address 4 will be highlighted in blue - touch IP Address 1 (it will have 50/51 in it)


Enter in 192 in first line press enter

Enter in 168 in 2nd line press enter

Enter in 1 in 3rd line press enter

Enter in 1 in 4th line press enter

Press CASH

Press cancel until back to the menu level screens



On Laptop

Open software - it is in c:\ebm\stock manager dec 22\


1. Setup

2. System

3. Got to the site (LOC) you're at and double click on it

4. Type in ip address of till (192.168.1.1 or see below)

5. Press ok

6. Press close


Send Changes

1. Tasks along the top

2. Send Changes

3. Scroll to the site name you're at and highlight it in blue

4. Press Retry and yes to carry out all jobs at this location


Should start counting blocks at bottom of box, if not, press timelog (sometimes this freezes for a while whilst it times out)



How to find IP address of TILL if you can't ping it / timelog says cannot connect 10060

ON TILL


- Payment

- 99

- MGR 1

- 9999 as password

- Payment

- Mode

- 7 PGM2 Mode

- Reading

- 34 Inline Config

- 1 Inline Preset


Show on screen or print it:


1# 192.168.1.1 etc.


If no response on time log this means till is in middle of transaction